Radial Diffuser Mounting Methods | rickardair

Radial Diffuser Mounting Methods

Click here for PDF Version

EXPOSED TEE CEILING GRID

  1. Drop-in Flush Mounting

  2. Drop-in Shadow Line

Flush Mounting and Shadow Line styles are available for 315 and 400mm Radials only. These can be supplied with the following mounting plate sizes, 595x595mm & 23¾x23¾” to suit 600x600mm & 24x24” ceiling grids respectively. Special sizes are available on request.

RVD-NP (Drop-in Flush Mounting)                                                         

    RVD (Shown) or RCD-NP (DROP-IN FLUSH MOUNTING)

MOUNTING IN FREE SPACE

  1. 4 Point Fixing (4 Brackets fitted to the round or square plenum for threaded rod connection)
  2. Hard Duct Connection (no accessories required)

RVD-NP (NO PLENUM)      

RVD-NP (NO PLENUM)

RCD-NP (NO PLENUM)

    RCD-NP (NO PLENUM)

 RVD-CP (CIRCULAR PLENUM)                                                         

    RVD or RCD-CP (CIRCULAR PLENUM)

RVD or RCD-SP (SQUARE PLENUM) FRONT VIEW

    RVD or RCD-SP (SQUARE PLENUM) FRONT VIEW

RVD-SP (SQUARE PLENUM SIDE VIEW)                                                              
    RVD or RCD-SP (SQURE PLENUM) SIDE VIEW

PLASTERED CEILING

  1. T-Ring (Circular Frame to allow Drop-in Flush Mounting)

Fixing of Radial diffusers in a plastered ceiling often presents a problem because of restricted access to the ceiling void. A T-Ring is available to allow Drop-in Flush Mounting of a standard Radial Diffuser. The T-Ring is mounted flush with the ceiling after a round hole is cut into the plaster board. Four threaded brackets draw the T-Ring flush against the ceiling to ensure a neat finish. NOTE: Do not overload the plastered ceiling. Attach safety wires to the RVD to reduce the load on the ceiling and to safeguard the occupants.

 T-RING FOR MOUNTING RVD'S IN PLASTERED CEILINGS

    T-RING FOR MOUNTING RVD'S IN PLASTERED CEILINGS

Dimensions

 T-RING GENERAL DIMENSIONS